| | | Variable Wavelength Detector |
| The UltiMate® 3000 Variable Wavelength Detector (VWD) is the detector of choice for routine chromatography applications. It offers high sensitivity, low noise and drift and a wavelength range of 190–900 nm. The VWD is available in two variants. The standard version with a 10 Hz data rate is economically affordable for laboratories on a limited budget. The rapid separation version offers a data rate of up to 100 Hz to perfectly detect even the narrowest peaks. Both detectors are designed to meet the demanding requirements of today’s laboratories. - Low noise (typically < ±2.5 µAU) and drift (< 0.1 mAU/h) guarantee high sensitivity
- Linear range of up to 2.5 AU allows for the analysis of wide range of analyte concentrations [more]
- Easily adaptable detector allows use with HPLC applications from nano- through to semi-preparative HPLC
- Data collection rates of up to 100 Hz allow detection of even the sharpest peaks
- Predictive performance technology continually monitors system performance and warns of impending errors such as lamp failure.
Performance Examples
| | | Variable Wavelength Detector Specifications | | Detection Type | Double beam forward optics design (monochromator) Single or multiple (4-channel) wavelength UV/VIS detector options | | Light Source | Deuterium lamp Optional tungsten lamp for visible wavelengths | | Noise | Typically < ±2.5 x µAU at 254 nm | | Drift | <0.1 mAU/hr at 254 nm | | Linearity | Up to 2.5 AU | | Wavelength Range | 190–900 nm (for wavelengths >600 nm, the tungsten lamp is required) | | Wavelength Bandwidth | 6 nm at 254 nm | | Data Collection Rate | Up to 100 Hz (VWD-3000RS Rapid Separation Variable Wavelength Detector) Up to 10 Hz (VWD-3000 Variable Wavelength Detector) | | Flow Cells | Standard: 11 µL volume, 10 mm path length. Semi-Micro: 2.5 µL volume, 7 mm path length. Semi-Preparative: 0.7 µL volume, 0.4 mm path length U-Z View Nano: 3 nL volume, 10 mm path length. U-Z View Cap: 45 nL volume, 10 mm path length. U-Z View Micro: 180 nL volume, 10 mm path length. | | GLP | Dionex AutoQTM routines for Instrument Qualification (IQ) Identification chips for lamps and flow cells. | | PC Connection | USB | | Analog Outputs | Two: absorbance, 20-bit resolution, 0–1 Volt and 0–10 Volt. | | Inputs/Outputs | Four inputs: remote Chart Mark, Autozero, Start Four outputs: error out (e.g., leak, lamp, error, etc.) | | Dimensions (h x w x d) | 15 x 42 x 50 cm (6 x 16 x 20 in.) | | Weight | 14.8 kg (32.6 lbs) |
| | Order Information | | VWD-3100 UltiMate 3000 Single Channel Variable Wavelength Detector | 5074.0005 | | VWD-3400 UltiMate 3000 Four Channel Variable Wavelength Detector | 5074.0010 | | Flow Cell for VWD-3x00, SST, 11 µL Volume, 10 mm Pathlength | 6074.0250 | | Flow Cell for VWD-3x00, PEEK, 11 µL Volume, 10 mm Pathlength | 6074.0200 | | Semi-micro Flow Cell for VWD-3x00, SST, 2.5 µL | 6074.0360 | | UZ-View Flow Cell Nano for VWD-3x00, 3 nL Volume | 6074.0270 | | UZ-View Flow Cell Cap for VWD-3x00, 45 nL Volume | 6074.0280 | | UZ-View Flow Cell Micro for VWD-3x00, 180 nL Volume | 6074.0290 | | Semi Preparative Flow Cell for VWD-3x00, PEEK, 0.7 µL Volume, 0.4 mm Pathlength | 6074.0320 | | D2-Lamp for VWD-3000 Series | 6074.1110 | | VIS-Lamp (Thungsten) for VWD-3000 Series | 6074.2000 | | Analog Output Board, VWD-3000 Series, Max. 2 Channels | 6074.0305 |
| |
|
|  |  | UltiMate LC and LC-MS Detectors | | Choose from a wide range of sensitive detectors. Operate even the MSQ™ Plus Mass Spectrometer, together with the other instruments in your system, from a single Chromeleon® control panel. |
| Modules | | | UltiMate ® 3000 LC modules achieve new levels of flexibility, performance, reliability, and ease of use. |
| LC and LC/MS Overview | Discover the UltiMate ® 3000 LCi series, and learn how LCi solutions can improve performance and productivity in your laboratory. |
| LCi Solutions |  | Find out how the UltiMate® 3000 LCi Series can provide you with LC solutions for your chromatographic challenges. |
|
|