| | | Acclaim Surfactant Column for separating all classes of Surfactants |  | Are you tired of the broad tailing peaks you get when separating cationic surfactants using reversed phase columns? Would you like to be able to separate all classes of surfactant using a single column? Introducing the Acclaim Surfactant column; the only column developed specifically for the analysis of surfactants.
Ideal selectivity for mixtures of surfactants Excellent peak shapes for cationic surfactants Compatible with highly aqueous mobile phases Improved resolution for ethoxylated surfactants Rugged separations under a variety of conditions Methods compatible with various detectors Broad range of applications.
When analyzing cationic surfactants by reversed phase chromatography, it is often difficult to obtain sharp, symmetrical peaks due primarily to the presence of free silanols on the silica. The Acclaim Surfactant columns feature a novel bonding chemistry that allows for effective deactivation of free silanols towards positively charged cationic surfactants, resulting in excellent peaks shapes. The Acclaim Surfactant column provides excellent resolution of surfactants over a broad range of applications using detectors ranging from UV-Vis, to suppressed conductivity, to evaporative light scattering (ELSD), to mass spectrometry. As a consequence of its novel chemistry, it exhibits a unique polarity that provides significantly improved resolution for individual oligomers of ethoxylated surfactants compared with conventional C18. The Acclaim Surfactant is also resistant to dewetting under highly aqueous mobile phase conditions, and thus can be used to provide excellent resolution between strongly hydrophilic compounds, such as isomers of xylene sulfonate. Each Acclaim Surfactant column is manufactured to stringent specifications to ensure column-to-column reproducibility. Each column is shipped with a lot validation sheet showing the test results and specifications for the lot of bonded silica Production columns are individually tested for capacity and efficiency, and closely monitored for metals contamination. Reproducible column-to-column manufacturing, the use of ultrapure silica, and performance validation of every column prior to shipping, all ensure that the quality of your separations will be maintained month to month and year to year. | | Acclaim Surfactant Column for separating all classes of Surfactants Specifications | | Endcapped | Yes | | Surface area | 300 m2/g | | pH range | 2.5–7.5 | | Temperature limit | < 60 oC | | Starting material | Ultrapure silica | | Particle size | 5 µm | | Metal impurity (Na, Fe, Al) | <10.0 ppm Total Metal <3.0 ppm Individual Metal | | Pore volume | 0.9–1.0 mL/g | | Average pore diameter | 120 Å | | Particle size distribution (40/90) | <1.3 | | Total carbon content | 12% | | Carbon chain length | C18 | | Particle shape | Spherical |
| | Order Information | | Acclaim Surfactant, 5 µm Analytical, (4.6 x 150 mm) | 063201 | | Acclaim Surfactant, 5 µm Analytical, (4.6 x 250 mm) | 063203 | | Acclaim Surfactant, 5 µm Guard Cartridges, (4.3 x 10 mm), 2 Each | 063215 | | SST Guard Cartridge Holder | 059456 | | Guard to Analytical Column Coupler | 059457 | | Guard Kit (Holder and Coupler) | 059526 |
| |
|
|  |  | Acclaim Mixed-Mode HILIC-1 Columns | | Acclaim® Mixed-Mode HILIC -1 columns are packed with a new silica-based stationary phase that incorporates both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties |
| Acclaim 120 Reversed-Phase Columns |  | The Acclaim® 120 columns are a highly characterized line of LC/MS compatible C18 and C8 phases that have very high surface coverage and very low metal content. These columns provide exceptional performance for a variety of applications in the pharmaceutical, nutraceutical, food, and life science separations areas. |
| New Acclaim RSLC Columns |  | The Acclaim® RSLC columns are designed to increase throughput while maintaining robust methods and ease of use. The columns are ideal for use with the Dionex UltiMate® 3000 RSLC system. The RSLC columns are available with well-established Acclaim reversed-phase packing for proven separation power and efficiency. |
|
|