AminoTrap Column for the Removal of Amino Acids During Carbohydrate Analysis

The AminoTrapTM is an in-line pretreatment column installed in place of the guard column, before a carbohydrate monosaccharide column.

  • In-line sample pretreatment column removes amino acids from samples for monosaccharide analysis.
  • Eliminates electrode fouling due to the presence of amino acids such as lysine.
  • Different dimensions are available for different monosaccharide analytical columns.

The detection of monosaccharides and amine-containing glycoconjugates with low levels of glycosylation can be compromised from fouling of the working electrode by amino acids. Amino acids such as lysine are potential interferents without the AminoTrap, because the oxidation products inhibit detector response for later-eluting monosaccharides.

The AminoTrap is an in-line pretreatment column installed in place of the guard column, before an analytical carbohydrate monosaccharide column, such as the CarboPacTM PA20 or CarboPac PA10. Specifically designed with high selectivity for amino acids, the AminoTrap column retains the amino acids, thus allowing the monosaccharides to be eluted well before interfering amino acids. In this way, the AminoTrap column eliminates working electrode fouling for samples such as glycoprotein hydrolysates or food sources that contain lysine.

The AminoTrap is packed with a 10-µm, high-capacity, anion-exchange resin that has high selectivity for hydrophobic amino acids relative to monosaccharides when using hydroxide eluents. The 4 × 50 mm AminoTrap is recommended for use with the CarboPac PA10. The 3 × 30 mm AminoTrap is recommended for use with the CarboPac PA20.

AminoTrap Column for the Removal of Amino Acids During Carbohydrate Analysis  Specifications
Contact your local representative for more information.
Order Information
Amino Trap Column (4 x 50 mm)046122
Amino Trap Column (3 x 30 mm)060146
AminoTrap Column (2 x 50 mm)SP5578
Data Sheets
CarboPac PA10   15K
CarboPac PA20 Analytical Column Manual   2MB
CarboPac MA1, PA1, PA10, PA100 Analytical Columns Manual   2MB
CarboPac PA1 and PA10 Columns for Mono- and Disaccharide Analysis Data Sheet   322K
CarboPac PA20 Column Data Sheet   135K
TN 40: Glycoprotein Monosaccharide Analysis Using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (HPAE-PAD)   268K
CarboPac PA10 Carbohydrate Column

The CarboPacTM PA10 is a specialized column for the high-sensitivity analysis of monosaccharides and disaccharides.

CarboPac PA20 Carbohydrate Column

The CarboPacTM PA20 is a strong anion-exchange column for high-resolution separations of mono- and disaccharides, with no need for derivatization.  

BorateTrap

The BorateTrapTM is a 4 × 50 mm column placed between the eluent pump and the injection valve to remove borate contamination from eluents used for HPAE-PAD.

Carbohydrate Standards

Dionex Monosaccharide and Oligosaccharide standards are intended for use in verifying the performance of your BioLC® system or CarboPacTM columns.

     
  Columns and Accessories > Bio Columns > Trap Columns for Bio Applications > AminoTrap Column for the Removal of Amino Acids During Carbohydrate Analysis  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com