| | | IonPac Fast Anion IIIA Anion-Exchange Column |  | The IonPac Fast Anion IIIA hydroxide-selective, anion-exchange column is specifically designed for the determination of phosphoric and citric acids in cola soft drinks. Its capacity and selectivity allows for the rapid analysis of these acids in less than 7 min. Recommended column for fast analysis of phosphoric and citric acids in cola soft drinks. Use with the eluent generator of a Reagent-FreeTM Ion Chromatography (RFICTM) system for simplified operation. Requires only a deionized water source to produce potassium hydroxide eluent. RFIC systems ensure excellent peak area and retention time precision for phosphoric acid. The 3-mm i.d. configuration provides economical operation. Eluent suppression using the ASRS® 300 or AAES® provides RFIC suppressed conductivity detection with low backgrounds and enhanced analyte sensitivity. Column selectivity is optimized for a 30 °C operating temperature to ensure reproducible retention times in all environmental conditions. Compatible with organic solvents to enhance analyte solubility, modify column selectivity, or allow effective column cleanup.
The cola samples may require sample pretreatment with sonication to remove carbonation. Sample dilution of cola syrups is recommended prior to analysis to ensure optimum column life. These acids can be analyzed in less than 7 min using an isocratic potassium hydroxide eluent delivered by an eluent generator in combination with suppressed conductivity detection. The Fast Anion IIIA Column is recommended for use with RFIC systems with eluent generation (RFIC-EGTM systems) that require only a deionized water source to produce potassium hydroxide eluent. The Fast Anion IIIA Column is rugged and reliable for the determination of phosphoric and citric acids in cola soft drinks. The Fast Anion IIIA Column is ideally used with RFIC technology for automatic eluent generation. Use the Anion Self-Regenerating Suppressor (ASRS 300, 2 mm) or the Anion Atlas Electrolytic Suppressor (AAES) with the Fast Anion IIIA Column for eluent suppression.
| | IonPac Fast Anion IIIA Anion-Exchange Column Specifications | | Dimensions | IonPac Fast Anion IIIA Analytical Column: 3 × 250 mm IonPac Fast Anion IIIA Guard Column: 3 × 50 mm | | Mobile phase compatibility | pH 0–14; 0–100% HPLC solvents | | Ion-exchange group | Functional Group: Alkanol quaternary ammonium ion | | Maximum operating pressure | 3000 psi | | Functional group characteristics | Hydrophobicity: Ultralow hydrophobic | | Capacity | 55 µeq (3 × 250 mm analytical column) 1.0 µeq (3 × 50 mm guard column) | | Column construction | PEEK with 10-32 threaded ferrule style end fittings. All components are nonmetallic. | | Substrate characteristics | Bead Diameter and Pore Size: 7.5 µm (3 × 250 mm); supermacroporous resin (2000 Å) 11 µm (3 × 50 mm); microporous resin (<10 Å) Cross-Linking (%DVB): 55% |
| | Order Information | | IonPac Fast Anion IIIA Analytical Column (3 x 250 mm) | 062964 | | IonPac Fast Anion IIIA Guard Column (3 x 50 mm) | 062966 |
| |
|
|  |  | SRS 300 |  | The Self-Regenerating Suppressor, (SRS® 300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity. |
| AES |  | The fifth-generation Atlas® Electrolytic Suppressor delivers very low noise with fast start-up and is tailored for use with carbonate and MSA eluents. It can also be used with hydroxide and even sulfuric acid. |
| ATC-HC Column |  | The IonPac® ATC-HC Anion Trap Column is a high-capacity, anion-exchange trap column designed for use with the EG40 or EG50 Eluent Generators. |
| ATC-3 Column |  | The IonPac® ATC-3 Anion Trap Column contains a high-capacity, low-efficiency, anion-exchange resin used to remove trace anion contamination from eluents. |
|
|