Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS17 Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS17 Anion-Exchange Column

The IonPac® AS17 is a low-capacity, hydroxide-selective, anion-exchange column designed for the determination of inorganic anions using gradient elution. The AS17 was designed specifically for use with the EG40 Eluent Generator.  Dionex has continued to provide hydroxide-selective columns for use with the EG40 and EG50 Eluent Generators.

  • Use the AS17 column in combination with the EG40 or EG50 Eluent Generator for the fast, gradient separation of the common inorganic anions at similar concentrations.
  • The AS17 column is ideal for the fast, gradient separation of sulfur species, including sulfite, sulfate, and thiosulfate.
  • Simplified Reagent-FreeTM Ion Chromatography (RFICTM) operation is provided by the EG40 or EG50 Eluent Generators, or the RFC-30 Controller, which requires only a deionized water source to produce potassium hydroxide eluent.
  • The IonPac AS18 column is the recommended hydroxide-selective column for the determination of the common inorganic anions in diverse sample matrices.

The IonPac AS17 column is designed for the fast, gradient separation of anions, including fluoride, acetate, chloride, nitrite, bromide, nitrate, sulfate, and phosphate, in a variety of sample matrices, such as drinking water, wastewater, foods and beverages, industrial cooling waters, and scrubber solutions. The AS17 column can resolve the common inorganic anions and acetate in less than 10 min using a 1.0–40 mM hydroxide gradient at a controlled temperature of 30 ºC coupled with suppressed conductivity detection. The AS17 provides excellent retention of fluoride from the water dip and baseline resolution of fluoride, acetate, propionate, and formate. The AS17 is recommended for RFIC technology using the EG40 or EG50 Eluent Generators, or the RFC-30 Controller. Use the Anion Self-Regenerating Suppressor (ASRS® ULTRA) with the AS17 column.

IonPac AS17 Anion-Exchange Column  Specifications
Maximum operating pressure

4000 psi

Mobile phase compatibility

pH 0–14; 0–100% HPLC solvents

Substrate characteristics

Bead Diameter: 10.5 µm

Cross-Linking (%DVB): 55%

Latex characteristics

Functional Group: Alkanol quaternary ammonium ion

Latex Cross-Linking: 6%

Latex Diameter: 75 nm

Hydrophobicity: Low

Capacity

7.5 µeq (2 × 250 mm analytical column)
1.5 µeq (2 × 50 mm guard column)

30 µeq (4 × 250 mm analytical column)
6 µeq (4 × 50 mm guard column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Dimensions

IonPac AS17 Analytical Column:
2 × 250 mm and 4 × 250 mm

IonPac AG17 Guard Column:
2 × 50 mm and 4 × 50 mm

Order Information
IonPac AS17 Analytical Column (4 x 250mm)055682
IonPac AS17 Analytical Column (2 x 250mm)055683
IonPac AG17 Guard Column (4 x 50mm)055684
IonPac AG17 Guard Column (2 x 50mm)055685
Data Sheets
IonPac AS17 Anion-Exchange Column Data Sheet   263K
IonPac AS17 Analytical Column Manual   1MB
AS18 Column
The IonPac®AS18 is the recommended hydroxide-selective column for inorganic anions in diverse sample matrices.
Ion Standards

The IonPac® ready-to-use ion standards are designed for routine anion or cation determinations.

SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

CR-TC Continuously Regenerated Trap Columns

Dionex's line of CR-TCs purify the eluent continuously.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS17 Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com