Columns and Accessories > IC and RFIC Columns > Cation Columns > IonPac CS15 Cation-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac CS15 Cation-Exchange Column

The IonPac® CS15 is a high-capacity, cation-exchange column designed for the determination of disparate concentration ratios of sodium and ammonium in diverse sample matrices. The new CS16 column is the column of choice for disparate concentration ratios of sodium and ammonium, and requires only an aqueous acid eluent for the analysis.

  • The CS15 can be used for disparate concentrations of sodium and ammonium. Solvent and elevated temperature are required for this separation.
  • The CS15 is recommended for trace ethanolamine in high-ammonium or high-potassium concentrations.
  • The CS15 can also be used for alkanolamines.
  • The CS16 column provides improved performance for disparate concentration ratios of sodium and ammonium without solvent in the eluent.
  • Sample matrices include environmental waters, power plant waters treated with ammonium, morpholine or ethanolamine, chemical additives, chemical process solutions, scrubber solutions, plating baths, and industrial solvents.

Using an isocratic acid or solvent eluent and elevated temperature (40 °C), coupled with suppressed conductivity detection, ratios of up to 8000:1 of sodium and ammonium can be determined. Use the Cation Self-Regenerating Suppressor (CSRS® ULTRA) with the CS15 column.

IonPac CS15 Cation-Exchange Column  Specifications
Dimensions

IonPac CS15 Analytical Column:
2 × 250 mm and 4 × 250 mm

IonPac CG15 Guard Column:
2 × 50 mm and 4 × 50 mm

Maximum operating pressure

27.6 MPa (4000 psi)

Mobile phase compatibility

Acidic eluents; 0–100% Acetonitrile. Alcohols should be avoided.

Substrate characteristics

Bead Diameter: 8.5 µm

Cross-Linking (%DVB): 55%

Functional group characteristics

Ion-Exchange Group: Carboxylic acid, phosphonic acid, and crown ether

Surface Characteristics: Medium hydrophilic

Capacity

700 µeq (2 × 250 mm analytical column)

2800 µeq (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac CS15 Analytical Column (4 x 250 mm)051795
IonPac CG15 Guard Column (4 x 50 mm)052200
IonPac CS15 Analytical Column (2 x 250 mm)052252
IonPac CG15 Guard Column (2 x 50 mm)052256
Data Sheets
IonPac CS15 Cation-Exchange Column Data Sheet   186K
IonPac CS15 Analytical Column Manual   451K
CS16 Column
The IonPac® CS16 is recommended column for disparate concentration ratios of sodium and ammonium.
SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

CR-TC Continuously Regenerated Trap Columns

Dionex's line of CR-TCs purify the eluent continuously.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

   
  Columns and Accessories > IC and RFIC Columns > Cation Columns > IonPac CS15 Cation-Exchange Column 
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com