IonPac AS22 Anion-Exchange Column

Designed specifically for compliance monitoring of inorganic anions in accordance with U.S. EPA Method 300.0 (A) and 300.1, the new IonPac® AS22 represents the culmination of more than 20 years of column development, and is a key part of our award winning Reagent-FreeTM  IC system, a revolutionary step in ion chromatography that requires only a source of deionized water to produce potassium carbonate/bicarbonate eluent.

  • Fast isocratic separation of the common inorganic anions in simple sample matrices in 6 minutes.
  • Isocratic separation of inorganic anion in complex sample matrices in 12 minutes.
  • Carbonate peak well-resolved from the common inorgainc anions.
  • Meets performance requirements specified in U.S. EPA Method 300.0 (A).
  • Ideal alternative for AS4A-SC, AS12A, AS14, and AS14A inorganic anion applications.
  • Simplified Reagent-Free IC operation provided by the EG50 Eluent Generator and EPM, which require only a deionized water source to produce potassium carbonate/bicarbonate eluent.
  • Simple, accurate eluent preparation with the AS22 Eluent Concentrate—just dilute in deionized water and start operation.
  • Eluent suppression using the ASRS® ULTRA or AAES® technology provides Reagent-Free IC operation with low backgrounds and enhanced analyte sensitivity.
  • High Capacity: 210 µeq/col. (4 x 250 mm column).
  • Operate at ambient or elevated temperatures. Column selectivity is optimized for a 30 °C operating temperature to ensure reproducible retention times.
  • Compatible with organic solvents to enhance analyte solubility, modify column selectivity, or for effective column cleanup.

The IonPac AS22 is a carbonate-based anion-exchange column designed for the determination of inorganic anions and low molecular weight organic acids including fluoride, acetate, formate, chloride, nitrite, bromide, nitrate, phosphate, and sulfate. The AS22 column can be used with isocratic carbonate/bicarbonate eluents and suppressed conductivity detection for the determination of inorganic anions. The AS22 column can be used in combination with the EG50 Eluent Generator and the Electrolytic pH Modifier (EPM) which automatically produces potassium carbonate/bicarbonate eluents from water. The AS22 column is an ideal alternative, using carbonate-bicarbonate eluents, for AS4A-SC, AS12A, AS14, and AS14A inorganic anion applications.

The IonPac AS22 column meets the performance requirements specified in U.S. EPA Method 300.0 (A). The common inorganic anions can easily be separated in a variety of sample matrices including drinking water, wastewater, process streams, and scrubber solutions. Use the Anion Self-Regenerating Suppressor (ASRS ULTRA II) or Anion Atlas® Electrolytic Suppressor (AAES) with the AS22 column for eluent suppression.

IonPac AS22 Anion-Exchange Column  Specifications
Substrate Characteristics:

Bead Diameter and Pore Size:
6.5 µm (2 x 250 and 4 x 250 mm); super macroporous resin (2000 Å)
11 µm (2 x 50 and 4 x 50 mm); microporous resin (<1 Å)

Cross-linking (%DVB): 55%

Ion Exchange Group:

Functional Group: Alkanol quaternary ammonium ion

Functional Group Characteristics:

Ultralow hydrophobicity

Column Construction:

PEEK with 10-32 threaded ferrule style end fittings. All components are nonmetallic.

Capacity:

52.5 µeq (2 x 250 mm analytical column)

210 µeq (4 x 250 mm analytical column)

1.5 µeq* (2 x 50 mm guard column)

6 µeq* (4 x 50 mm guard column)

*Guards are packed with a low-capacity microporous resin.

Dimensions:

IonPac AS22 Analytical Column:
2 x 250 mm and 4 x 250 mm

IonPac AG22 Guard Column:
2 x 50 mm and 4 x 50 mm

Maximum Operating Pressure:

3000 psi

Mobile Phase Compatibility:

pH 0–14; 0–100% HPLC solvents

Order Information
IonPac AS22 Analytical Column (2 x 250 mm)064137
IonPac AG22 Guard Column (2 x 50 mm)064135
IonPac AS22 Analytical Column (4 x 250 mm)064141
IonPac AG22 Guard Column (4 x 50 mm)064139
AS22 Eluent Concentrate (100x), 250 mL063965
Data Sheets
IonPac AS22 Datasheet   432K
IonPac AS22 Analytical Column Manual   441K
AES

The fifth-generation Atlas® Electrolytic Suppressor delivers very low noise with fast start-up and is tailored for use with carbonate and MSA eluents. It can also be used with hydroxide and even sulfuric acid.

SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

Ready-Made Reagents

Ready-made reagents and concentrates simplify your chromatography, and reduce the risk of eluent contamination.

New — Award-Winning ICS-3000 RFIC™ System

The ICS-3000 Reagent-Free™ IC system won an Editors' Choice Silver Award as one of the best new products at Pittcon '05. The ICS-3000 allows chemists to save time, labor, and operating cost while increasing the productivity and reproducibility of ion analysis for any application.

   
  Columns and Accessories > IC and RFIC Columns > Carbonate-Based Anion Columns > IonPac AS22 Anion-Exchange Column 
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com