ICS-900 Entry-Level IC System Specifications
|
|
Pump
|
|
Type
|
Serial dual-reciprocating piston, microprocessor-controlled constant stroke, variable speed
|
|
Construction
|
Chemically inert, metal-free PEEK pump heads and flow paths compatible with aqueous eluents of pH 0–14 and reversed-phase
solvents
|
|
Pump Operating Pressure
|
0–35 MPa (0–5000 psi)
|
|
Flow Rate Range
|
0.00 mL/min to 5.00 mL/min with settable flow increment at 0.01 mL/min without changing pump heads
|
|
Flow Precision
|
<0.1%
|
|
Flow Accuracy
|
<0.1%
|
|
Pressure Ripple
|
<1%
|
|
Eluent Bottle Pressure
|
None required
|
|
Vacuum Degasser
|
Optional with external vacuum degasser
|
|
Gradient Capabilities
|
Optional with RFC-30
|
|
Eluent Generation
|
Optional with RFC-30
|
|
Injection Valve
|
6-port, 2-position Rheodyne valve, electrically activated
|
|
Column Heater/ Thermostat
|
Optional External Heater CTS-10, 25 to 85 ˚C, minimum 5 ˚C above ambient
|
|
Suppressors and Control
|
|
Chemical Suppression
|
Yes, anion and cation, 2 and 4 mm
|
|
Displacement Chemical Regeneration
|
Yes, anion and cation, 2 and 4 mm
|
|
Electrolytic Suppression, Self-Regenerating
|
Yes with RFC-10
|
|
Electrolytic Suppression, Self-Regenerating with External Water
|
Yes with RFC-10
|
|
Suppression Capacity
|
Anion SRS 300 (4 mm): 200 µeq/min Cation SRS 300 (4 mm): 110 µeq/min Anion SRS 300 (2 mm): 50 µeq/min Cation SRS 300 (2 mm): 37.5 µeq/min Anion MMS 300 (4 mm): 150 µeq/min Cation MMS 300 (4 mm): 150 µeq/min Anion MMS 300 (2 mm): 37.5 µeq/min Cation MMS 300 (2 mm): 37.5 µeq/min Anion AES: 25 µeq/min Cation AES: 25 µeq/min AMMS-ICE : N/A
|
|
Void Volume
|
SRS 300 (4 mm): <50 µL SRS 300 (2 mm): <15 µL MMS 300 (4 mm): <50 µL MMS 300 (2 mm): <15 µL AMMS-ICE 300 (4 mm): <50 µL AMMS-ICE 300 (2 mm): <15 µL Anion AES: <35 µL Cation AES: <35 µL
|
|
Sequential Suppression for Anions
|
Yes, MMS + CRD 300
|
|
Suppressor Wear Parts
|
None; peristaltic pump and inline filters not required
|
|
Detector
|
|
Conductivity Detector
|
Bipolar heated conductivity cell, microprocessor-controlled digital signal processing over the range 0–10,000 µS/cm
|
|
Detector Linearity
|
1%
|
|
Maximum Cell Pressure
|
10 MPa (1500 psi)
|
|
Resolution
|
0.0047 nS/cm
|
|
Cell Calibration
|
Factory calibrated as a new system and calibrated in the field individually with memory retention and transfer
|
|
Flow Cell Chemical Compatibility (standard)
|
Fully compatible with all typical Ion Chromatography eluents including MSA
|
|
AutoSampler
|
|
Automation Using Autosampler
|
Yes, Dionex AS40, AS-HV, AS Autosamplers or third party
|
|
Sequential/Simultaneous Injection
|
Yes, depending on autosampler capabilities
|
|
Automated Dilution
|
Yes, available with AS Autosampler
|
|
Dilution Factor, AS Autosampler
|
1:1 to 1:1000
|
|
Dilution Time, AS Autosampler
|
15 seconds with sample overlap
|
|
Inline Sample Degassing
|
Optional with CRD 300/200
|
|
Inline Filtration
|
AS40 Autosampler or inline filter
|
|
Automation Flexibility
|
High, conditionals using Chromeleon softwareand post run features
|
|
Semiautomated System Qualification
|
Yes, IQ/OQ/PQ
|
|
System Software
|
|
Software
|
Chromeleon Chromatography Management Software, requires Microsoft Windows® 2000, XP, or Vista
|
|
Automated Procedure Wizards
|
Yes, standard feature
|
|
System Wellness and Predictive Performance
|
Yes, standard feature
|
|
Virtual Column Simulator
|
Yes; evaluation mode standard,
isocratic and gradient optional
|
|
Application Templates
|
Yes, standard feature
|
|
Multivendor Automation Support of 3rd Party
|
Yes, fully controls over 300 different instruments from more than 30 manufacturers, including GC, HPLC, and MS
|
|
Customizable System Control Panels
|
Yes, standard feature
|
|
System Status Virtual Channels
|
Yes, standard feature
|
|
Power Failure Protection
|
Yes, standard feature
|
|
Sequential Injection
|
Yes, standard feature for independent dual system analysis
|
|
System Trigger Commands and Conditionals
|
Yes, standard feature
|
|
Daily Audit Trail
|
Yes, standard feature
|
|
Sample Audit Trail
|
Yes, standard feature
|
|
Multiple Network Control and Network Failure Protection
|
Yes, optional
|
|
System Calibration Storage
|
Yes, factory, present and previous. Completely user selectable
|
|
Customized Reporting
|
Yes, standard feature with unlimited report workbooks
|
|
Physical Specifications
|
|
Dimensions (h × w × d)
|
33 × 24 × 40 cm (13 × 9.5 × 15.75 in.)
|
|
Weight
|
10 kg (22 lb)
|
|
Power Requirements
|
100–240 V ac, 50–60 Hz, autoranging
|
|
System Flow Path
|
All polymeric (PEEK), anion or cation configurations
|