| | | | Autosampler Column Compartment
|
| The UltiMate® ACC-3000 Autosampler Column Compartment is a cost-effective solution ideally suited for routine analyses in the pharmaceutical, food and beverage, and environmental industries. A variety of different sample formats combined with large sample capacity support a wide range of every-day, routine applications. The integrated autosampler and column oven module offers performance and flexibility that exceed the requirements of most analytical methods. As a single module, it reduces the height and the cost of the automated system. - Minimal sample carry-over [more]
- Wide application flexibility using up to five different sample vial formats in the same sequence
- Re-sealable sample compartment, with patented temperature control to protect thermal sensitive samples
- Accurate column temperature control for reproducible chromatographic results
- Eluent preheating for increased chromatographic reliability at high temperatures
- Easy front access to all fluidic components
- Trouble free operation due to minimized wear and tear
- Chromeleon® Chromatography Management Software for system control, qualification procedures and intuitive troubleshooting
Precise, accurate injections with minimal carryover The rugged pulled-loop design of the autosampler ensures optimal performance across a wide range of sample volumes [more]. Injection volumes are very precise in both full loop and partial loop mode [more ]. The integrated wash port cleans both inner and outer needle surfaces, eliminating virtually any possibility of carry-over.
 The pulled-loop injection principle of the ACC-3000 provides optimal performance across a wide range of injection volumes and requires minimal maintenance effort.
| | | Autosampler Column Compartment
Specifications | | Sample Capacity | 3 × 40 vials (1.8 mL) or 3 × 72 vials (1.2 mL) or 3 × 22 vials (4 mL) or 3 × 10 vials (10 mL) plus 3 × 5 vials (10 mL) | | Injection Technique | Pulled loop, with programmable needle wash | | Injection Methods | Pulled loop, using full loop or partial loop fill | | Injection Volume Precision | < 0.25% RSD in full loop mode (20 µL loop) Typically < 0.3% RSD in partial loop mode at 5 µL (20 µL loop) | | Linearity | Corr. coeff. > 0.9995, RSD < 1% in partial loop mode for 1–10 µL (20 µL loop) Corr. coeff. > 0.9995, RSD < 0.5% in partial loop mode for 10–100 µL (200 µL loop) | | Carryover | < 0.02% with caffeine | | Injection cycle time | Typically < 45 seconds with 5 µL injection | | Optional Sample Thermostatting | 8–40 °C, max. 15 °C below ambient | | Column temperature range: | 5 °C above ambient to 50 °C | | Dimensions (h x w x d) | 40 x 42 x 51 cm (16 x 16.5 x 20 in.) | | PC Connection | USB; USB hub with 3 sockets integrated | | Additional Specifications | Please see data sheet |
| | Order Information | | ACC-3000 UltiMate 3000 Autosampler with Integrated Column Compartment | 5830.0010 | | ACC-3000T UltiMate 3000 Thermostatted Autosampler with Integrated Column Compartment | 5830.0020 |
| |
|
|  |  | Injectors and Autosamplers | | UltiMate® 3000 Injector and Autosampler Series delivers new levels of performance, reliability, and ease of use. |
| Modules | | | UltiMate ® 3000 LC modules achieve new levels of flexibility, performance, reliability, and ease of use. |
| LC and LC/MS Overview | Discover the UltiMate ® 3000 LCi series, and learn how LCi solutions can improve performance and productivity in your laboratory. |
| LCi Solutions |  | Find out how the UltiMate® 3000 LCi Series can provide you with LC solutions for your chromatographic challenges. |
|
|