| | | | Refractive Index Detector |
| Need to detect analytes with limited or no UV absorption? Does your HPLC method require detection of alcohols, sugars, saccarides, fatty acids, or polymers? Then the RI-101 refractive index detector is the perfect choice. High sensitivity is assured, reducing the noise level to less than 2.5 nRIU. For fast results, an optimized temperature control system ensures fast baseline stabilization after system start-up. Ease of use is obtained through a start-up sequence that automates purging, equilibration, autozero, and the control of baseline stability and noise. In addition, a full-color, liquid-crystal display provides fast access to instrument settings and performance parameters, and shows an on-line signal.
|
•
Get Your Results Fast
•
Easy Setup and Usage
•
Save Time Through Automated Validation
|  | Get Your Results Fast
The innovative and very sophisticated temperature control makes the RI-101 ready to use in less than 40 min after start-up. The built-in start-up sequence automates otherwise cumbersome and time-consuming processes such as purging and control of baseline stability and noise. |  | Easy Setup and Usage
A full-color liquid-crystal display shows an on-line signal and provides fast access to instrument settings and performance parameters. Operation with Chromeleon® software makes the detector easy to use and ensures maximum productivity in instrument control, data processing, and reporting of results. |  | Save Time Through Automated Validation
Automated validation functions save time and make validation of the instrument an easy task. The detector provides information on noise, drift, lamp age, lamp voltage, and temperature. A “Span” function verifies accurate signal response for a defined standard solution. Powerful and easy to use, AutoQTM validation routines allow for automated Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ) tests. | | Refractive Index Detector Specifications | | Measuring Method | Deflection method | | Refractive Index Range | 1.00–1.75° | | Measuring Range | 1/4–512 μRIU | | Linearity Range | 600 μRIU | | Noise Level | Less than 2.5 nRIU, response: 1.5 s | | Flow Cell | 8 μL; 0.05 MPa (7.5 psi) pressure maximum | | Dead Volume | Less than 600 μL | | Max. Flow Rate | 10 mL/min with water | | Temperature Control | 30–50 °C in 1 °C steps | | Automated Start-Up Functions | Purge cycles Equilibration Autozero Baseline drift Noise verification | | Validation Functions | Noise Drift Temperature Lamp age Lamp voltage Accuracy (determined filling the detector cell with a defined standard solution) | | Display | Color liquid-crystal display, allows for real-time baseline monitoring | | Analog Outputs | Integrator, 0–1 V Recorder, 0–10 mV | | Contact Closure Inputs | Autozero Marker Polarity Purge on/off | | Contact Closure Outputs | Ready Solvent leak Error | | Communication | RS-232 | | Power Consumption | 150 VA Max. | | Dimensions (h × w × d) | 26 × 20 × 40 cm (10.1 × 7.8 × 15.6 in.) | | Weight | 12 kg (27 lb) |
| | Order Information | | RI-101 Differential Refractive Index Detector | 5060.0030 |
| |
|
|  |  | UltiMate LC and LC-MS Detectors | | Choose from a wide range of sensitive detectors. Operate even the MSQ™ Plus Mass Spectrometer, together with the other instruments in your system, from a single Chromeleon® control panel. |
| Modules | | | UltiMate ® 3000 LC modules achieve new levels of flexibility, performance, reliability, and ease of use. |
| LC and LC/MS Overview | Discover the UltiMate ® 3000 LCi series, and learn how LCi solutions can improve performance and productivity in your laboratory. |
| LCi Solutions |  | Find out how the UltiMate® 3000 LCi Series can provide you with LC solutions for your chromatographic challenges. |
|
|